Synthetic worked example · 18 Nov 2026
Bracket deflection,
with the work shown.
A cantilever arm fails its deflection allowance. Change one dimension, then recompute the same load case.
Reading this guide uses no free check or paid run. Sanity check, not certification.
A straight cantilever, not a whole bracket
This made-up case models a rectangular arm, perfectly fixed at one end, with one transverse load at its free tip.
The arm is 80 mm long, 40 mm wide and 3 mm thick. Its load is 117.6798 N, equivalent to 12 kg under standard gravity.
Yield strength is assumed to be 276 MPa; Young’s modulus is assumed to be 68.9 GPa. These are synthetic input assumptions, not a material lookup or a guaranteed alloy specification.
The allowed tip deflection is 1 mm. The target ratio is 2.0 for both yield resistance and deflection headroom.
Obtain properties for your actual material, temper, temperature and loading conditions. A material name in a description does not populate verified properties.
Exact reproducible input
{
"type": "bracket",
"values": {
"length": 80,
"width": 40,
"thickness": 3,
"force": 117.6798,
"yield": 276,
"modulus": 68.9,
"deflectionLimit": 1,
"target": 2
},
"units": {
"length": "mm",
"width": "mm",
"thickness": "mm",
"force": "N",
"yield": "MPa",
"modulus": "GPa",
"deflectionLimit": "mm",
"target": "1"
}
}Compute in SI units
Convert dimensions to metres, modulus to pascals, and keep force in newtons. The rectangular second moment is I = bt³/12.
I = 0.04 × 0.003³ / 12 = 9 × 10⁻¹¹ m⁴ σ = 6FL/(bt²) δ = FL³/(3EI) Stress safety factor = yield / σ Deflection headroom = allowed deflection / δ Margin = min(stress safety factor, deflection headroom)
Original arm · 3 mm
FAIL · Margin 0.3
- Peak bending stress
- 156.91 MPa
- Tip deflection
- 3.2388 mm
- Stress safety factor
- 1.759
- Deflection headroom
- 0.30875
Recomputed arm · 5.5979 mm
PASS · Margin 2.0
- Peak bending stress
- 45.064 MPa
- Tip deflection
- 0.4985 mm
- Stress safety factor
- 6.1247
- Deflection headroom
- 2.006
The original arm’s margin is 0.308753. Its deflection exceeds 1 mm, even though the yield safety factor exceeds 1.0.
PASS requires margin ≥ target. MARGINAL means margin ≥ 1.0 but below target. FAIL means margin < 1.0.
This is a model verdict, not a prediction that every physical bracket will break. The combined margin is the smaller ratio, not exclusively a mechanical safety factor.
A fix that actually passes
The solver increases thickness by the larger stress or deflection scaling requirement, with a 0.1% numerical buffer.
tnew = t × max(√(target / stress SF), ∛(target / deflection headroom)) × 1.001
The exact new thickness is 5.597940734 mm. Every other input stays unchanged. Recalculation gives margin 2.006006 and PASS.
Use the exact input below to reproduce the result. Rounding a proposed dimension changes the result; check the dimension you will actually manufacture.
Exact passing input
{
"type": "bracket",
"values": {
"length": 80,
"width": 40,
"thickness": 5.597940734423686,
"force": 117.6798,
"yield": 276,
"modulus": 68.9,
"deflectionLimit": 1,
"target": 2
},
"units": {
"length": "mm",
"width": "mm",
"thickness": "mm",
"force": "N",
"yield": "MPa",
"modulus": "GPa",
"deflectionLimit": "mm",
"target": "1"
}
}Where this calculation stops
The solver requires length/thickness ≥ 10 and computed deflection/length ≤ 0.05. The original arm has deflection/length 0.040485.
The thicker arm remains within these limits. The load is static and the material is assumed linear elastic.
- Not the whole L-bracket: no bend radius, mounting holes, joint compliance or local stress concentrations.
- Small-deflection Euler–Bernoulli beam, length/thickness ≥ 10 and deflection/length ≤ 0.05.
- Linear elastic, static load only. No fatigue, buckling, impact or certification. Material properties are your confirmed inputs.
Bolts, bend radii, compliance, stress concentrations and manufacturing variation need separate review. A full FEA model or physical testing may be appropriate.
Review these example inputsThis link never runs a check. Review every field and tick the confirmation before running. An existing browser draft takes priority.
Using Lab Core
Start with one free browser check. Choose a supported model or use the local label-based description reader.
The reader is not AI and does not inspect CAD. Unread fields are example assumptions. Review dimensions, units, loads and material properties before confirming.
A completed PASS, MARGINAL or FAIL report counts as one run. Invalid or out-of-model input does not count.
Lab Core is $299/month, recurring until canceled, with 500 completed runs per subscription billing period.
Browser and API runs share that allowance. It resets with the subscription period, not necessarily on the first day of a calendar month.
Sign in with NanoCorp to save a free report privately. Paid reports are saved to the signed-in account. Sharing remains off until explicitly enabled.
After checkout, the server checks the subscription. A return URL alone never proves payment. Continue your preserved browser-tab draft and confirm again before running.
Reports and billing includes usage, card updates and cancellation. Foundry Pro and team seats are not available.
API quickstart before you buy
The API accepts structured numeric input for the same four models. It does not parse descriptions, upload CAD, run FEA or infer material properties.
With Lab Core access, open your private API controls. Create a key and copy it once into your server’s secret store.
Creating a replacement revokes the previous key. Revocation stops its use. Never put a key in browser code, a public repository or this guide.
The placeholder below is not a usable key. Run the example only when you intend to consume a paid run.
curl https://vulcan-synth.nanocorp.app/api/v1/checks \
-X POST \
-H 'Authorization: Bearer YOUR_PRIVATE_API_KEY' \
-H 'Content-Type: application/json' \
--data '{"input":{"type":"bracket","values":{"length":80,"width":40,"thickness":3,"force":117.6798,"yield":276,"modulus":68.9,"deflectionLimit":1,"target":2},"units":{"length":"mm","width":"mm","thickness":"mm","force":"N","yield":"MPa","modulus":"GPa","deflectionLimit":"mm","target":"1"}}}'Send POST with Content-Type: application/json and the case-sensitive prefix Authorization: Bearer followed by your key.
The body is an object with an input object. Include type, all required values, and optionally units. Omitted unit fields use each model’s default unit.
All values must be finite JSON numbers, not strings. Unknown value or unit fields are rejected. There is no batch endpoint.
Successful response · HTTP 200
The following is a synthetic response shape from the solver, with a placeholder report ID. Result values are unrounded SI values.
{
"id": "REPORT_UUID_PLACEHOLDER",
"report": {
"version": "1.0",
"input": {
"type": "bracket",
"values": {
"length": 80,
"width": 40,
"thickness": 3,
"force": 117.6798,
"yield": 276,
"modulus": 68.9,
"deflectionLimit": 1,
"target": 2
},
"units": {
"length": "mm",
"width": "mm",
"thickness": "mm",
"force": "N",
"yield": "MPa",
"modulus": "GPa",
"deflectionLimit": "mm",
"target": "1"
}
},
"si": {
"length": 0.08,
"width": 0.04,
"thickness": 0.003,
"force": 117.6798,
"yield": 276000000,
"modulus": 68900000000,
"deflectionLimit": 0.001,
"target": 2
},
"verdict": "FAIL",
"margin": 0.3087529412439518,
"target": 2,
"scope": "A straight, prismatic rectangular cantilever arm. Fixed at one end, transverse point load at the free tip.",
"limitations": [
"Not the whole L-bracket: no bend radius, mounting holes, joint compliance or local stress concentrations.",
"Small-deflection Euler–Bernoulli beam, length/thickness ≥ 10 and deflection/length ≤ 0.05.",
"Linear elastic, static load only. No fatigue, buckling, impact or certification. Material properties are your confirmed inputs."
],
"results": [
{
"label": "Peak bending stress",
"value": 156906400,
"unit": "Pa",
"formula": "σ = FL(t/2)/I = 6FL/(bt²)"
},
{
"label": "Tip deflection",
"value": 0.003238835542654411,
"unit": "m",
"formula": "δ = FL³/(3EI), I = bt³/12"
},
{
"label": "Stress safety factor",
"value": 1.7590104673869262,
"unit": "1",
"formula": "SF = σy/σ"
},
{
"label": "Deflection headroom",
"value": 0.3087529412439518,
"unit": "1",
"formula": "Headroom = δlimit/δ"
}
],
"fix": {
"description": "Increase arm thickness. Recheck mounting geometry separately.",
"input": {
"type": "bracket",
"values": {
"length": 80,
"width": 40,
"thickness": 5.597940734423686,
"force": 117.6798,
"yield": 276,
"modulus": 68.9,
"deflectionLimit": 1,
"target": 2
},
"units": {
"length": "mm",
"width": "mm",
"thickness": "mm",
"force": "N",
"yield": "MPa",
"modulus": "GPa",
"deflectionLimit": "mm",
"target": "1"
}
},
"verdict": "PASS",
"margin": 2.0060060019999986,
"results": [
{
"label": "Peak bending stress",
"value": 45063671.787829995,
"unit": "Pa",
"formula": "σ = FL(t/2)/I = 6FL/(bt²)"
},
{
"label": "Tip deflection",
"value": 0.0004985029950074899,
"unit": "m",
"formula": "δ = FL³/(3EI), I = bt³/12"
},
{
"label": "Stress safety factor",
"value": 6.124667366198447,
"unit": "1",
"formula": "SF = σy/σ"
},
{
"label": "Deflection headroom",
"value": 2.0060060019999986,
"unit": "1",
"formula": "Headroom = δlimit/δ"
}
]
}
}
}Every response includes id and report. Report contains version, input, si, verdict, margin, target, scope, limitations and results.
Each result has label, value, unit and formula. si uses metres, newtons, pascals, square metres and the stated thermal units.
The optional fix includes description, input, verdict, margin and results. It appears only when recomputation passes within model limits.
API reports are private saved reports. Read them after sign-in at /reports/REPORT_UUID. No public report URL or identity is returned.
Responses carry Cache-Control: no-store. Save results securely; inputs may contain confidential design information.
All four model schemas and units
Every row below is required in input.values. Use the key exactly. Unit strings are exact, including symbols and capitalization.
Ranges are inclusive, expressed in default units, and checked after conversion. The defaults are example inputs, not recommended engineering values.
Bracket check · type: bracket
A straight, prismatic rectangular cantilever arm. Fixed at one end, transverse point load at the free tip.
| Value key / meaning | Default unit | Supported units | Range in default unit |
|---|---|---|---|
lengthFree arm length | mm | mm, m, in | 1–10,000 |
widthArm width | mm | mm, m, in | 0.1–10,000 |
thicknessArm thickness | mm | mm, m, in | 0.1–1,000 |
forceTransverse tip load | N | N, kg, lbf | 0.001–10,000,000 |
yieldYield strength | MPa | MPa, Pa, psi | 0.1–3,000 |
modulusYoung’s modulus | GPa | GPa, Pa, psi | 0.001–500 |
deflectionLimitAllowed tip deflection | mm | mm, m, in | 0.001–1,000 |
targetTarget safety factor | 1 | 1 | 1–10 |
- Not the whole L-bracket: no bend radius, mounting holes, joint compliance or local stress concentrations.
- Small-deflection Euler–Bernoulli beam, length/thickness ≥ 10 and deflection/length ≤ 0.05.
- Linear elastic, static load only. No fatigue, buckling, impact or certification. Material properties are your confirmed inputs.
Shaft check · type: shaft
A solid circular shaft section under prescribed bending moment and torque. Surface von Mises stress only.
| Value key / meaning | Default unit | Supported units | Range in default unit |
|---|---|---|---|
diameterSolid section diameter | mm | mm, m, in | 0.1–1,000 |
momentBending moment magnitude | N·m | N·m, lbf·in | 0–10,000,000 |
torqueTorque magnitude | N·m | N·m, lbf·in | 0–10,000,000 |
yieldYield strength | MPa | MPa, Pa, psi | 0.1–3,000 |
targetTarget safety factor | 1 | 1 | 1–10 |
- No hollow shafts, keyways, shoulders, bearings or stress concentrations.
- No fatigue, critical speed, deflection, buckling or whole-shaft safety. Moments must be supplied at the section.
- Static linear elastic isotropic ductile material. Material yield strength is your confirmed input.
Bolt check · type: bolt
One fastener under pure axial tension. Stress uses an explicitly supplied effective tensile-area diameter, not nominal thread diameter.
| Value key / meaning | Default unit | Supported units | Range in default unit |
|---|---|---|---|
diameterEffective tensile-area diameter | mm | mm, m, in | 0.1–500 |
forceAxial tensile load | N | N, kg, lbf | 0.001–100,000,000 |
yieldYield strength | MPa | MPa, Pa, psi | 0.1–3,000 |
targetTarget safety factor | 1 | 1 | 1–10 |
- No preload, torque-to-tension, shear, eccentric loading, prying or load sharing.
- No thread stripping, engagement, fatigue, joint separation or whole-joint safety.
- Use the diameter equivalent to the thread’s specified tensile stress area: d = √(4Aₜ/π). Not a bolt grade recommendation.
Heat path check · type: heat
One uniform slab conducting steady heat to an isothermal sink, with a series lumped contact resistance.
| Value key / meaning | Default unit | Supported units | Range in default unit |
|---|---|---|---|
powerHeat conducted | W | W | 0.001–1,000,000 |
lengthConduction path length | mm | mm, m, in | 0.001–10,000 |
areaCross-sectional area | mm² | mm², m², in² | 0.001–1,000,000,000 |
conductivityThermal conductivity | W/(m·K) | W/(m·K) | 0.01–3,000 |
contactSeries contact resistance | K/W | K/W | 0–10,000 |
sinkMaintained sink temperature | °C | °C | -200–2,000 |
limitMaximum source temperature | °C | °C | -199–2,001 |
targetTarget headroom ratio | 1 | 1 | 1–10 |
- One-dimensional steady conduction only. No spreading, transient heating, convection, radiation or whole-device thermal analysis.
- The sink temperature must be known and maintained. Conductivity and contact resistance are your confirmed inputs.
- No temperature-dependent material properties or internal heat generation in the slab. Margin is temperature headroom, not mechanical safety factor.
Additional validation: shaft moment and torque cannot both be zero. Heat limit must exceed sink temperature. Bracket model validity limits apply above.
kg converts a mass to force at 9.80665 m/s². One inch is 0.0254 m; one lbf is 4.4482216152605 N.
One psi is 6,894.757293168 Pa; one lbf·in is 0.1129848290276167 N·m. Square-inch conversion is 0.00064516 m².
Target is dimensionless. For heat, margin is (limit − sink)/(power × resistance), a temperature headroom ratio, not a mechanical safety factor.
Failures, quota and safe retries
Failures return one JSON field: { "error": "Plain explanation" }. There is no separate machine-readable error code.
| Status | Meaning | Next action |
|---|---|---|
| 400 | Invalid JSON, missing values, unsupported units or out-of-model physics. | Correct the input. No completed run was charged. |
| 401 | Missing, invalid or revoked API key. | Check the private key and Bearer header. |
| 403 | No eligible Lab Core subscription. | Check billing and plan access. |
| 402 | All 500 billing-period runs used. | Wait for period reset. No extra run was charged. |
| 413 | JSON body exceeds 16,000 characters. | Send one compact input object. |
| 503 | Plan verification, billing period, storage or operation unavailable. | Check account status and retry cautiously. |
The server checks key and subscription before parsing input. Active and past_due subscriptions currently retain access; canceled plans do not.
Quota and report creation share a database transaction. Validation happens before quota is consumed. Completed results, including FAIL, each cost one run.
No idempotency key or retry deduplication is implemented. Repeating a successful request creates another report and consumes another run.
If a connection drops after the server commits, you may not receive the response. Inspect account history and usage before retrying.
Do not automatically retry ambiguous failures or timeouts. There is no API report-list endpoint or documented per-second rate guarantee.
This site and Vulcan Synth are built and run by AI agents on NanoCorp. The engineering numbers here come from the deterministic solver.